HomeSignal · Development project
Single-Family 244 WESTVIEW TERRACE
Replace/reconstruct approximately 20 linear feet of damaged exterior stud wall framing and approximately four linear feet of interior stud wall framing along the south elevation. The affected wall framing is approximately eight feet in height and consists of 2x4 wood studs spaced approximately 16 inches on center. • Carefully remove the brick veneer from the damaged first floor wall area, extending from grade to approximately the second-floor level, as necessary to access and reconstruct the damaged wall framing. • Provide temporary shoring and support for the existing brick veneer above the repair area. The upper brick veneer can remain in place provided it is adequately supported throughout the repair. • Reconstruct the removed portion of the brick veneer and properly tie the replacement veneer to the repaired wall framing., Arlington (76013), TX
Residential · Proposed as of
On the record
- Address
- Replace/reconstruct approximately 20 linear feet of damaged exterior stud wall framing and approximately four linear feet of interior stud wall framing along the south elevation. The affected wall framing is approximately eight feet in height and consists of 2x4 wood studs spaced approximately 16 inches on center. • Carefully remove the brick veneer from the damaged first floor wall area, extending from grade to approximately the second-floor level, as necessary to access and reconstruct the damaged wall framing. • Provide temporary shoring and support for the existing brick veneer above the repair area. The upper brick veneer can remain in place provided it is adequately supported throughout the repair. • Reconstruct the removed portion of the brick veneer and properly tie the replacement veneer to the repaired wall framing.
- Type
- Residential
- Where it stands
- Proposed
- Status as of
- Date on record
- (filed)
- Record number
- 082147
- Source
- City of Arlington (arlington-permit-applications)
- Official record
- View the source record
Where it is
On the HomeSignal page for this ZIP code:
More projects in Arlington (76013)
- Residential 2200 BRIGADOON COURT 2200 BRIGADOON COURT Residential · Approved
- Residential 1500 W LOVERS LN SUITE 310 Scope of Work – Exterior Wall Damage Repair Tuscany Square Apartments – Unit 310 1500 Lovers Lane, Arlington, TX 76013 Remove damaged portions of the exterior wall assembly and reconstruct to match existing conditions. Work includes: Remove damaged exterior brick veneer and mortar as required. Remove damaged sheathing, insulation, weather barrier/flashing, and interior drywall. Remove and replace damaged wood wall framing as required, subject to structural engineer review. Inspect existing window and surrounding framing; protect and repair/reinstall flashing as required. Install new wood framing to match existing 16" O.C. framing where applicable. Replace insulation, exterior sheathing, weather-resistant barrier/flashing, and related components. Reconstruct exterior brick veneer to match existing brick as closely as practical. Replace interior drywall, tape, texture, and baseboard/trim in repaired areas. Seal and weatherproof all repaired exterior interfaces. Final finishes to match existing conditions. Structural: Existing wall framing and window opening are to be reviewed by a qualified structural engineer. Any required header, framing, connections, shoring, or other structural requirements shall be determined by the engineer and incorporated into the permitted repair. Permit scope: Exterior wall repair/reconstruction due to damage, including associated structural, weatherproofing, masonry, insulation, and interior finish repairs. Residential · Proposed
- Utility & Miscellaneous 2120 REFLECTION BAY DR CELL1 T-Mobile DA04671S 2114 Reflection Drive, Arlington, TX Removal of antennas, cabinets and supporting equipment. Roads & infrastructure · Proposed
- Residential 2200 BRIGADOON COURT Fire Damage/Repair of Three-Unit Residence. Scope of work is to remove and replace fire damage framing, primarily the west portion of the roof and some roof framing; garage framing; replace all windows, replaced damaged drywall and any damaged framing member; replace HVAC system; and replaced damaged electrical wiring. Replace any plumbing in the garages that was damaged. Residential · Approved (no longer tracked)
- Single-Family 4640 PLUMPJACK DRIVE 4640 Plumpjack Drive - New Single Family Residential Residential · Proposed (no longer tracked)
Status as of , from City of Arlington's public records. The name, address, record number, date and status are the source's own; nothing on this page is generated or inferred.